15 Parameter reference
15.2 Parameter list
858
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00189
C00190
C00191
Parameter | Name:
C00189 | Resp. to too frequent AutoFailReset
Data type: UNSIGNED_8
Index: 24386
d
= 5F42
h
Response to exceeding the maximum number of "AutoFailReset" processes set in C00186.
AutoFailReset function
Selection list (Lenze setting printed in bold)
0 No Reaction
1Fault
2Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00190 | L_NSet_1: Setpoint arithmetic
Data type: UNSIGNED_8
Index: 24385
d
= 5F41
h
The L_NSet_1 FB: Selection of arithmetics
• To be able to influence the main setpoint (NSet) by an additional setpoint (NAdd).
Selection list (Lenze setting printed in bold)
0Out = Set
1Out = Set + Add
2 NOut = NSet - NAdd
3 NOut = (NSet * NAdd) / 100%
4 NOut = (NSet * 1%) / |NAdd|
5 Out = (Set*100%)/(100%-Add)
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00191 | Logbook access index User
Data type: UNSIGNED_8
Index: 24384
d
= 5F40
h
From version 12.00.00
Logbook read interface
Setting range (min. value | unit | max. value)
0 255
Subcodes Lenze setting Info
C00191/1 255 Logbook access index User
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1