Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 939
15 Parameter reference
15.2 Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00621/112 0: Not connected LS_ParReadWrite_1: bReadWrite
Read/write request 1: Selection of reading/writing
C00621/113 0: Not connected LS_ParReadWrite_2
: bExecute
Read/write request 2: Trigger
C00621/114 0: Not connected LS_ParReadWrite_2
: bReadWrite
Read/write request 2: Selection of reading/writing
C00621/115 0: Not connected LS_ParReadWrite_3
: bExecute
Read/write request 3: Trigger
C00621/116 0: Not connected LS_ParReadWrite_3
: bReadWrite
Read/write request 3: Selection of reading/writing
C00621/117 0: Not connected LS_ParReadWrite_4
: bExecute
Read/write request 4: Trigger
C00621/118 0: Not connected LS_ParReadWrite_4
: bReadWrite
Read/write request 4: Selection of reading/writing
C00621/119 0: Not connected LS_ParReadWrite_5
: bExecute
Read/write request 5: Trigger
C00621/120 0: Not connected LS_ParReadWrite_5
: bReadWrite
Read/write request 5: Selection of reading/writing
C00621/121 0: Not connected LS_ParReadWrite_6
: bExecute
Read/write request 6: Trigger
C00621/122 0: Not connected LS_ParReadWrite_6
: bReadWrite
Read/write request 6: Selection of reading/writing
C00621/123 0: Not connected LS_WriteParamList
: bExecute
Writing the parameter list: Activate
C00621/124 0: Not connected LS_WriteParamList
: bSelectWriteValue_1
Writing to parameter list: Selection of value set - 1
C00621/125 0: Not connected LS_WriteParamList
: bSelectWriteValue_2
Writing to parameter list: Selection of value set - 2
C00621/126 0: Not connected LS_CANManagement
: bResetNode
Reset CAN node
C00621/127 0: Not connected LS_CANManagement
: bReInitCAN
Reinitialise CAN interface
C00621/128 0: Not connected LS_DigitalInput
: bPosIn12_Load
Frequency input DI1/DI2: Load angle integrator with
starting value and reset status signal
C00621/147 0: Not connected LS_TouchProbe
: bDisableTPDigIn3
TP input DI3: Disable TP function dynamically
C00621/148 0: Not connected LS_TouchProbe
: bDisableTPDigIn4
TP input DI4: Disable TP function dynamically
C00621/149 0: Not connected LS_TouchProbe
: bDisableTPDigIn5
TP input DI5: Disable TP function dynamically
C00621/150 0: Not connected LS_TouchProbe
: bDisableTPDigIn6
TP input DI6: Disable TP function dynamically
C00621/151 0: Not connected LS_TouchProbe
: bDisableTPDigIn7
TP input DI7: Disable TP function dynamically
C00621/152 0: Not connected LS_TouchProbe
: bDisableTPDigIn3_Rising
TP input DI3: Disable recognition of rising edges
dynamically
C00621/153 0: Not connected LS_TouchProbe
: bDisableTPDigIn3_Falling
TP input DI3: Disable recognition of falling edges
dynamically
Parameter | Name:
C00621 | System connection list: Bool
Data type: UNSIGNED_16
Index: 23954
d
= 5D92
h