Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 947
15 Parameter reference
15.2 Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00659
C00660
C00661
C00662
Parameter | Name:
C00659 | PRBS duration
Data type: UNSIGNED_16
Index: 23916
d
= 5D6C
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C00660 | L_FixSet_a_1: Analog values
Data type: INTEGER_16
Index: 23915
d
= 5D6B
h
From version 04.00.00
FB L_FixSet_a_1
: Setting of the fixed values
Setting range (min. value | unit | max. value)
-199.99 % 199.99
Subcodes Lenze setting Info
C00660/1 0.00 % Fixed value 0 ... 15
C00660/...
C00660/16
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00661 | L_FixSet_w_1: Fixed values
Data type: UNSIGNED_16
Index: 23914
d
= 5D6A
h
From version 04.00.00
FB L_FixSet_w_1
: Setting of the fixed values
Setting range (min. value | unit | max. value)
0 65535
Subcodes Lenze setting Info
C00661/1 0 Fixed value 0 ... 15
C00661/...
C00661/16
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00662 | L_FixSet_w_2: Fixed values
Data type: UNSIGNED_16
Index: 23913
d
= 5D69
h
From version 04.00.00
FB L_FixSet_w_2
: Setting of the fixed values
Setting range (min. value | unit | max. value)
0 65535
Subcodes Lenze setting Info
C00662/1 0 Fixed value 0 ... 15
C00662/...
C00662/16
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1