Clear Log
Use this to remove all the current information in the Event log. This affects both the viewed log and the printed log
information.
To clear the event log:
1 From the Diagnostics menu, navigate to:
Event Log > Clear Log
2 Choose any of the following:
Yes—To clear the Event log
No—To exit the Clear log menu
Scanner tests
“ASIC Test” on page 196
“Motor tests” on page 196
“Feed test” on page 197
“Sensor tests” on page 197
“Scanner calibration reset” on page 200
“ADF magnification” on page 200
ASIC Test
This setting initiates a scan of the scanner ASIC’s memory.
To perform this test, do the following:
1 Navigate to Scanner Tests > ASIC Test.
2 The test executes. While this test executes, the screen displays ASIC Test Running.... If the scanner ASIC
passed the test, then the panel posts ASIC Test Passed. Rebooting.... If the scanner ASIC failed the
test, then the panel posts ASIC Test Failed. Rebooting....
Motor tests
ADF pick
When Motor On is selected, the device runs the pick motor continuously for five seconds and then automatically stops
the motor.
To perform this test, do the following:
1 Navigate to Scanner Tests >Motor Tests.
2 Select ADF pick.
The test will run if it is working properly.
Flatbed scanner motor
When Motor On is selected, the device moves the flatbed scanner along the entire flatbed scanner path (that is, to the
far wall and back to the Home position) and then automatically stops at the Home position.