Crane operation
11.5 Crane operation with main boom
Operating manual 3 302 736 en 11 - 95
GMK4090
xx.xx.xxxx
Inspections prior
to starting opera-
tions
When the ignition is turned on, CCS registers the displayed telescoping sta-
tus from the current status of the telescoping mechanism and the previ-
ously saved locking and unlocking procedures.
Normally, CCS detects differences between the current and the displayed
telescoping and displays the corresponding error message;
à Malfunctions
in the telescoping mechanism
, p. 14 - 17.
If a malfunction results in values being deleted, CCS can no longer calculate
the current telescoping and will not issue an error message.
• Before the first telescoping, compare the telescoping indicated on the
CCS
display with the current telescoping.
You must enter the current telescoping if the current telescoping is not dis-
played correctly;
à Current telescoping, p. 11 - 100.
s
S
Risk of damage to the telescoping mechanism
Before the first telescoping, always check whether the
CCS display is show-
ing the current telescoping.
This prevents the telescoping mechanism being damaged when
telescoping.

Table of Contents

Other manuals for Manitowoc GROVE GMK4090

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc GROVE GMK4090 and is the answer not in the manual?

Manitowoc GROVE GMK4090 Specifications

General IconGeneral
BrandManitowoc
ModelGROVE GMK4090
CategoryConstruction Equipment
LanguageEnglish

Related product manuals