222 SyncServer 600 Series User’s Guide 098-00720-000 Revision D1 – February, 2018
Chapter 6 Provisioning
Provisioning Outputs
The SyncServer only support TAI timescale. The ARB timescale is not used.
Per the enterprise profile specification, the PTP output will not be enabled until the
UTC offset is known. This must be manually entered on the Timing - Input Control
Window page if the system has not obtained this information from the reference. For
example, the UTC offset must be manually entered for IRIG references.
Table 6-18. Editing Existing PTP Server Output
Method Steps Notes
Web Interface Network Timing > NTPr/PTP Config
1. Use the Service dropdown box to
select PTP master in the desired
row.
2. Click the blue Configure icon in the
Configure column of that row.
3. Change the parameter settings to
the desired values. Click OK.
4. Click the Apply button.
Network Timing > NTP/PTP Mapping
1. Use the NTPr/PTP Service Name
dropdown box to select the PTP
service name for the desired port.
2. Click the Apply button.
Map PTP master to the
desired LAN port.
CLI n/a n/a
Front Panel n/a n/a