5-2
SETTING OF REGISTER MARK DETECT
This function detects a register mark automatically. Use this function to correct the inclination of the sheet loaded, the
position of plotting origin, and the distance between register marks and then cut the contour of printed image.
If the firmware version is older than 2.50, the register mark is circular.
How to display the register mark setting on LCD
1. Display the LOCAL menu page 3
Press key several times.
2. Select [MODE SET]
3. Display the MODE SET page 6.
Press key several times.
4. Select [MARK SENSOR].
In the case of no sensor model, page 6 is not
displayed.
If [expand] is set to ON, can not select Mark
sensor.
Change the setting to OFF.( P. 4-15)
[LOCAL]
TOOL SELECT ―――
CONDITION ―――
TEST CUT ―――
[LOCAL]
INTERFACE ―――
MODE SET ―――
SELF TEST ―――
< MODE SET >
Z STROKE
MULTI–PASS ―――
VACUUM AutoOFF >
< MODE SET >
MARK SENSOR ――
EXPAND OFF—>
RESERVE
<DETECT SET>
DETECT OFF
SIZE 10
STYLE Square