TROUBLES FOR WHICH ERROR MESSAGES ARE GIVEN ON THE LCD
If something is wrong with the device, a corresponding error message is given on the LCD.
Causes of and corrective measures against such errors are described below.
Errors that can be corrected by users
The table below gives the errors that can be corrected by users.
Error message Cause Corrective measure
ERROR 10 COMMAND
ERROR 11 PARAMETER
ERROR 12 DEVICE
Communication conditions on the
device are different from those on
the computer.
Adjust the communication conditions on
the device to those on the com-
puter.( P. 1-19)
ERROR 13 POLYGON Polygon buffer has overflown. Divide first the polygon data,
then transmit the divided polygon data.
ERROR 20 I/O Communication conditions on the
device are different from those on
the computer.
Adjust the communication conditions on
the device to those on the com-
puter.( P. 1-19)
Power to the computer and that to
the device are turned on in the
wrong order.
Turn on the power to the computer first,
then turn on the power to the device.
ERROR 27 BUFFER OVER An abnormal condition has arisen
in the serial interface.
Adjust the communication conditions on
the device to those on the com-
puter.( P. 1-19)
ERROR 30 OPERATION Improper key operation is carried
out such as a change in the commu-
nication conditions while cutting or
other performance of the device is
interrupted.
Do not conduct any improper key opera-
tion.
The effective area is smaller than
A3 and ASCII damp is executed.
Set the effective area to A3 size (297 x
420 mm) or more. Then, execute ASCII
damp.
The origin is set to a position where
the effective area of A3 size is not
ensured, and ASCII damp is exe-
cuted.
ERROR 31 NO DATA Copy function is executed in the
case where no data is received.
Transmit data to be copied from the
computer to the device.
Then cut a pattern according to the data.
Then, execute the copy function.( P.
4-4)
ERROR 32
DATA IS TOO LARGE
Size of data to be copied exceeds 1
MB.
Transmit data of which size is smaller
than 1 MB.