1-25
Setting for automatic head retract [AUTO VIEW]
A period of time required to cause the head to start to travel to its retracted position after the completion of cutting
(plotting).
If the blower is powered on, it switches off after the head has automatically retracted.
Set values
OFF: Automatic head retract is not performed.
1s: When one second has passed after the completion of cutting (plotting), the head starts to travel to the
retracted position
3s: When three second has passed after the completion of cutting (plotting), the head starts to travel to the
retracted position
1. Press the key several times until the LCD indicates
page 3 of the LOCAL MENU.
2. Select the [MODE SET].
3. Press the key until the LCD indicates page 2 of the
[MODE SET].
4. Set the [AUTO VIEW] to one of the following.
OFF, 1s, 3s
[LOCAL] 1 / 4
TOOL SELECT ――― >
CONDITION ――― >
TEST CUT ――― >
[ LOCAL] 3 / 4
INTERFACE ――― >
MODE SET ――― >
SELF TEST ――― >
<MODE SET> 1/6
Z STROKE *7mm >
MULTI–PASS ――― >
VACUUM * AutoOFF >
< ODE SET > 2 / 6
AUTO VIEW ∗ OFF >
DUMMY CUT ∗ ON >
ONE STROKE ∗ OFF >