Bytes 063
Name Type of data Function
Byte 2 Bit 0: reset power failure (power
fail)
Bit 1: reset error
Bit 2: weights as DINT
Bit 3: zero
Bit 4: tare
Bit 5: reset tare
Bit 6: lling mode
Bit 7: read material from the
material table
BOOL Bit 0:
rising edge
Bit 1:
rising edge: resets the error ag and error
code.
Bit 2:
status-controlled:
Value: 0 = Real, 1 = DINT
Bit 3:
rising edge
Bit 4:
rising edge
Bit 5:
rising edge
Bit 6:
status-controlled: 0 = ll, 1 = empty
Bit 7:
rising edge: A valid material ID is required
in byte 3. Filling does not start.
This function can be used to display materi-
al parameters on external displays.
Byte 3 Material ID BYTE
Value range: 110
Byte 47
Set point DINT/REAL Weight
Byte 811
Preset DINT/REAL Preset point for switching from coarse ow
to ne ow.
Byte 1215
Material overshoot (OVS) DINT/REAL Weight
Byte 1619
Calming time DINT [ms]
Byte 2023
Tolerance above set point DINT/REAL Weight
Byte 2427
Tolerance below set point DINT/REAL Weight
12.3.5.2 Read window EasyFill → PLC
The data required for monitoring and controlling lling does not t in a 64-byte write
window. For this reason the system dierentiates between system and material
parameters. The value of the rst byte can be used to determine whether the data refers
to the system or the material.
12.3.5.2.1 System data
Before starting lling, a check must be carried out to ensure that the system is ready
(byte 3: bit 2).
The Dosing_Run bit is set once lling has successfully started.
Bytes 063
Name Type of data Function
Byte 0 TableSelect USINT Content of read data:
0 = system data, 1 = material data
12 Fieldbus interface X3 Process Indicator PR 5410
EN-309 Minebea Intec