Specications
Description Data
Connection D-Sub female connector, 37-pin
Input: Qty 6
Input: Voltage
Low: 05 V DC or open
High: 1031 V DC
Passive, external power supply required
Input: Current <7 mA @ 24 V
<3 mA @ 12 V
protected against incorrect polarity
Output: Qty 12
Output: Voltage Max. switching voltage: 32 V DC
Max. switching current: 25 mA
Voltage drop @ 25 mA: 3 V
Protected against incorrect polarity
Passive, external power supply required
4 Device installation X3 Process Indicator PR 5410
EN-87 Minebea Intec