3-110
4. Select the desired parameter by pressing the box.
5. To navigate through the machine parameter settings:
• The bits are ranged from 7 (left) to 0 (right).
• Press [
]
or [
]
of the cursor key to move the cursor.
• Press <0> or <1> on the numeric keys, or [ ] or [ ], to change the bit value.
• Press [Enter] to save the setting of the displayed parameter and return to the machine parameter
edit screen.
• Press [Back] not to save the setting of the displayed parameter.
6. If you want to set other parameters, repeat step 3-5. Otherwise, proceed to step 7.
7. Press <Reset> to return the machine to ready screen.
You can confirm the initial setting of each parameter by the network switch list.
The network switch list will be printed by pressing [Parameter Print] in step 2.
Network switch 000~001: Factory use only
Network switch 002:
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Maximum session times of
SMTP
Set up the maximum session times.
The number between 1 to 32 are available.
00011111 32 times
:
00001001 10 times
:
00000001 2 times
00000000 1 time (default)
6 0
5 0
4 0
3 0
2 0
1 0
0 0
Network switch 003:
Switch
Initial
Setting
Adjust Usage/Comments
7 0 Number of retry times for
archive transmission
Set up the retry times for archive transmission.
This setting is adopted for the following transmission
when an available destination is set.
• Transmission to a shared folder
• E-mail transmission
11111111 255 times
:
00001111 15 times (default)
:
00000001 1 time
00000000 No retry
6 0
5 0
4 0
3 1
2 1
1 1
0 1