4-7
4.5 Communication trouble
4.5.1 Fax communication error
Deatail error code are printed on T.30 monitor.
Phase Error code
Detail
Error code
Description Journal Redial Message
Note
Tx Phase A D.0.1 0001 Local busy detection. No Yes The sending was stopped. Please try again.
D.0.2 0002 Busy Tone detected The line was busy. Please try again.
D.0.3 0003 Canceled transmission while dialing No Fax job was cancelled by user. Occurs at broadcast with
TCR.
D.0.7 0007 Receiver does not answer Yes Check condition of remote fax.
D.0.8 0008 Can not detect dial tone No dial tone detection. Check line connection.
D.0.10 000A Check condition remote of fax. No NCU board (Modem) malfunction or NCU connection
error.
Please check the connection and replace the NCU
board if needed.
Tx Phase B T.1.1 1011 T1 time-out error Yes Only
when one
or more
pages are
received
Confirm the remote fax.
T.2.1 1021 Can not detect CFR or FTT No Confirm the remote fax.
T.2.2 1022 Compatibility error Confirm the remote fax.
1100 Password transmission failed ID check Tx error. ID was not matched.
1101 Cannot obtain password at
password transmission from
receiving party
ID check Tx error. No fax number stored in remote
fax.
1102 The obtained password from
receiver at password transmission
is blank
1103 The receiver is a product of other
maker at closed communication
Close Tx error. Remote fax is not compatible.
1104 The receiver has no pass code field
at closed transmission
Close Tx error. No pass -code stored in remote fax.
1105 The pass code did not match at
closed transmission
Close Tx error. Passcode unmatched.
1109 Cannot adjust communication data
rate
Confirm the remote fax. Normally, this error does
not occur.
110A Cannot adjust the communication
mode (Normal, fine, super fine)
110B Cannot receive standard frame
110C DIS T4 bit did not turn ON