NIGHT CONNECTION-FIXED
NIGHT CONNECTION-FLEXIBLE
– 361 –
A2356-10
To provide the Night Announcement by Digital Announcement Trunk for a DID call, do the follow-
ing programming in addition to the programming of “DIRECT INWARD DIALLING (DID)”.
page 222
DESCRIPTION DATA
Assign the Digital Announcement Trunk
card number to the required LEN.
NOTE: The Digital Announcement Trunk
card number must be assigned
to the first LEN (Level 0), the
third LEN (Level 2), the fifth LEN
(Level 4), and the seventh LEN
(Level 6) of each LT slot.
(1)
(2)
000-763: LEN
EB002-EB127:
Digital Announcement Trunk Card No.
For PIM0/1: EB002-EB031
For PIM2/3: EB032-EB063
For PIM4/5: EB064-EB095
For PIM6/7: EB096-EB127
NOTE: EB000 and EB001 are dedi-
cated to built-in Digital An-
nouncement Trunk of the MP
card.
Assign the Service Restriction Class A for
Digital Announcement Trunk Access
(Record/Replay/Delete) to required sta-
tion.
(1)
(2)
Y=02
X-XXXXXXXX: Station No.
XX ZZ
XX: 00-15 : Service Restriction Class
A
Allow Digital Announcement Trunk Access
in the Service Restriction Class A as-
signed by CM12 Y=02.
(1)
(2)
Y=33
00-15: Service Restriction Class A as-
signed by CM12 Y=02
1 : Allow
Assign the Digital Announcement Trunk to
each incoming trunk.
(1)
(2)
Y=05
Direct-In Termination in Night Mode
000-255: Trunk No.
EB000-EB001: Built-in DAT on MP card
EB002-EB127: Digital Announcement
Trunk Card No. as-
signed by CM10
Provide the received digit conversion to
the DID trunk routes assigned by CM30
Y=00.
(1)
(2)
Y=18
00-63: Trunk Route No.
0: To provide
CM12
CM15
CM30
START
CM10
A
CM35

Table of Contents