Macro Reference
682
Vision System FH/FZ5 Series
User’s Manual (Z340)
Example
Saves the processing units of Processing Unit number 2 to Processing Unit number 4 of the current scene in
a processing unit data file.
Useable Modules
Scene Control Macro / Communication Command Macro
Supported Versions
Version 3.50 or later
Related Items
Rem Save Processing Unit number 2 to Processing Unit number 4 of the current scene in a processing unit data file.
SaveUnitData -1, 2, 3, "C:\BACKDIR\unitsave.unt"
GetSystemData (Reference: X Details (p.546)) LoadUnitData (Reference: X Details (p.607))
SaveBackupData (Reference: X Details (p.669)) SaveData (Reference: X Details (p.670))
SaveScene (Reference: X Details (p.675)) SaveSceneGroup (Reference: X Details (p.677))
SaveSystemData (Reference: X Details (p.679)) SceneNo (Reference: X Details (p.691))
UnitNo (Reference: X Details (p.790)) Ut (Reference: X Details (p.793))

Table of Contents

Other manuals for Omron SYSMAC FH Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC FH Series and is the answer not in the manual?

Omron SYSMAC FH Series Specifications

General IconGeneral
BrandOmron
ModelSYSMAC FH Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals