PG-FP6 V1.06 Appendix A. Messages
R20UT4469EJ0800 Rev.8.00 Page 169 of 188
Oct.01.21
An error occurred during execution of the ‘gos’ command. This might be due to a problem
with communications between the FP6 and target device. Refer to section 12.2, Problems
during Operation.
Communication
failure or timeout.
An error occurred during execution of the ‘pfo’ command. In some target devices, one of
the problems described as responsible for error Nos. 094, 108, 587, 590, 591, or 592
might have occurred.
Communication
failure or timeout.
The FP6 main unit might be damaged. Contact a Renesas Electronics sales representative
or distributor.
Power Failure
detected.
The FP6 main unit might be damaged. Contact a Renesas Electronics sales representative
or distributor.
-(No display)-
The FP6 main unit might be damaged. Contact a Renesas Electronics sales representative
or distributor.
NAND flash -
ECC error
The FP6 main unit might be damaged. Contact a Renesas Electronics sales representative
or distributor.
NAND flash -
Timeout
Execute the ‘init’ command (click on the [Initialize FP6] button in the [FP6 Options] dialog
box selected from the FP6 Terminal menu). The FP6 main unit might be damaged if the
error cannot be fixed. Contact a Renesas Electronics sales representative or distributor.
NAND flash -
Redirection block
not found
The FP6 main unit might be damaged. Contact a Renesas Electronics sales representative
or distributor.
NAND flash -
Mapping Error
The FP6 main unit might be damaged. Contact a Renesas Electronics sales representative
or distributor.
NAND flash -
Mapping Error
The FP6 main unit might be damaged. Contact a Renesas Electronics sales representative
or distributor.
FP6
Configuration -
Erase/Write fail
The FP6 main unit might be damaged. Contact a Renesas Electronics sales representative
or distributor.
FP6 Statistics -
Erase/Write fail
The firmware of the FP6 is incorrect.
This error may occur when the power of the FP6 main unit is turned off during updating the
version of firmware.
Contact a Renesas Electronics sales representative or distributor.
Firmware data is
invalid.
830 ProgareaSize err There is no space in the programming area although the required programming area was
reserved when the parameter file was downloaded.
Other programming areas must be erased.
requires setting of
a larger
programming
area