PG-FP6 V1.06 4. Usage of the FP6 Terminal
R20UT4469EJ0800 Rev.8.00 Page 67 of 188
Oct.01.21
4.6 Example of Operation Using the FP6 Terminal
This chapter explains a series of basic FP6 operations using the FP6 Terminal, taking a case where the
RL78/G14 is used as the target device as an example.
• Series of operations described in this chapter:
The operation conditions for this chapter are as follows.
Host PC interface: USB
Active programming area: Area 0
Target device: R5F104PJ (RL78/G14)
Power supply: 5 V supplied from the FP6
Clock supply: 32 MHz (on-chip oscillator clock)
Communications interface: Single-wire UART (1 Mbps)
Security setting: Disabled
Block setting: Operations are to be on all blocks.
Flash options: Not used
The operation steps described in this chapter are as follows.
(1) Installing the FP6 Terminal and USB driver
(2) Connecting the FP6 to the host PC
(3) Connecting the target system
(4) Starting up the FP6 Terminal
(5) Setting up a programming environment
(6) Executing the [Start] command
(7) System shutdown
4.6.1 Installing the FP6 Terminal and USB driver
Refer to chapter 3, Software Installation, and install the FP6 Terminal and the USB driver on the host PC.
4.6.2 Connecting the FP6 to the host PC
1. Connect the USB connector of the FP6 to the USB port on the host PC via a USB cable.
2. Connect the power adapter (which comes with the FP6) to the FP6.
3. Turn on the power switch on the FP6. Do not connect the target device before turning on power.
4.6.3 Connecting the target system
Be sure to turn on the power of the FP6 before connecting the target system.
1. Connect the GND connector of the FP6 to the target system via the GND cable.
Note: The FP6 and target system may be damaged if there are differences in potential between the
grounds of the FP6 and of the target system. Use the GND cable to eliminate differences in potential
before connecting the target cable.
2. Connect the target connector of the FP6 to the target system via the target cable.
Note: Connect the target system before supplying V
CC
power from the target system.