Zones Parameters By Category Type
Quick keys Parameter Default Range

Type
The Zone Type menu contains parameters that enable you to program the
zone type for any zone.
1) Select the zone (ZZZ) and then press OK.
2) Then scroll to select the zone type (35 types – see below), and press OK.
Note
Zones for partial arming (“Stay” arming) must be defined as Interior type.
Available options:
: Interior+Exit/Entry 1, : Interior +Entry follower
: Interior+Exit/Entry 2, : Interior+Instant
: Interior+Exit(OP)/Entry
Quick keys Parameter Default Range
ZZZ

Not Used
Disables a zone. All unused zones should be given this designation
ZZZ

Exit/Entry 1
Used for Exit/Entry doors. Violated Exit/Entry zones do not cause an
intrusion alarm during the Exit/Entry delay. If the zone is not secured by
the end the delay expires it will trigger an intrusion alarm.
To start an arming process, this zone should be secured. When system is
armed, this zone starts the entry delay time (see ).
ZZZ

Exit/Entry 2
Arm/Stay
Same as above, except that the Exit/Entry 2 time period applies
ZZZ

Exit (OP)/Entry 1
Used for an exit/entry door, open during the armed period.
This zone behaves as described in the Exit/Entry 1 parameter, shown
above, except that, if faulted when the system is being armed, it does not
prevent arming.
To avoid an intrusion alarm, it must be secured before the expiration of the
Exit Delay period.