Quick keys Parameter Default Range
ZZZ

Exit (OP)/Entry 2
Same as above , except that the Exit (Op)/Entry 2 time period applies.
ZZZ

Entry Follower
Usually assigned to motion detectors and to interior doors protecting the
area between the entry door and the keypad.
This zone(s) causes an immediate intrusion alarm when violated unless an
Exit/Entry zone was violated first. In this case, Entry Follower zone(s) will
remain bypassed until the end of the Entry Delay period.
ZZZ

Instant
Usually intended for non-exit/entry doors, window protection, shock
detection, and motion detectors.
Causes an immediate intrusion alarm if violated after the system is armed
or during the Exit Delay time period.
When Auto Arm and Pre-Warning are defined, the instant zone will be
armed at the end of the Pre-Warning time period.
ZZZ

I+ Exit/Entry 1 (Interior+ Exit/Entry 1)
Used for Exit/Entry doors, as follows:
If the system is armed in the Away (full) arming mode, the zone(s)
provide a delay (specified by Exit/Entry 1) allowing entry and exit
to-and-from the armed premises.
If the system is armed in the Stay mode, the zone is bypassed.
Important
For greater security when arming in the partial (Stay) arming mode, it is
possible to eliminate the Entry Delay period associated with any zone(s),
classified as Exit/Entry Delay 1 by pressing the key twice, one after
another. In effect, this makes it an instantly-armed zone.
ZZZ

I + Exit/Entry 2
(Interior + Exit/Entry 2)
Same as the I+Exit/Entry 1 parameter, described above, but the
Exit/Entry 2 time period is applicable.