Quick keys Parameter Default Range
ZZZ

I + Exit(OP)/Entry 1
Interior + Exit(OP)/Entry 1)
Used for an exit/entry door that, for convenience, may be kept open when
the system is being armed, as follows:
In full (Away) arming mode behaves as an Exit (Op)/Entry 1 zone
(see ZZZ above).
In partial (Stay) arming mode, the zone will be bypassed.
ZZZ

I + Exit(OP)/Entry 2
Interior + Exit(OP)/Entry 2)
Used for an exit/entry door that, for convenience, may be kept open when
the system is being armed, as follows:
In full (Away) arming mode behaves as an Exit (Op)/Entry 2 zone
(see ZZZ above).
In partial (Stay) arming mode, the zone will be bypassed.
ZZZ

I+ Entry Follow
(Interior + Entry Follower)
Generally used for motion detectors and/or interior doors (for example,
foyer), which would have to be violated after entry in order to disarm the
system, as follows:
In full (Away) arming mode behaves as an Entry Follower zone.
(see
ZZZ above)
In partial (Stay) arming mode, the zone will be bypassed.
ZZZ

I + Instant (Interior + Instant)
Usually intended for non-exit/entry doors, window protection, shock
detection and motion detectors.
In full (Away) arming) mode behaves as an intruder (instant) zone.
In partial (Stay) arming mode, the zone is bypassed.
ZZZ

UO Trigger
For a device or zone, which if violated at any time triggers a previously
programmed utility output, and is capable of activating an external
indicator, relay, appliance, and so on.