Quick keys Parameter Default Range
ZZZ

Special
For external auxiliary emergency alert buttons and wireless auxiliary
emergency transmitters.
If violated, an immediate auxiliary emergency alarm is sounded,
regardless of the system’s state and a report is sent to the monitoring
station.
ZZZ

Key Switch
Used to arm/disarm the system.
Connects an external momentary action key switch to any zone terminals
given this designation.
ZZZ

Final Exit
Zones of this type must be the last detector to be activated on exit or the
first detector to be activated on entry. When arming the system, the related
partition arms 10 seconds after this zone is closed, or opened and then
closed. After triggered once the zone acts as an exit (open)/entry 1 zone.
ZZZ

Latch Key Switch
Connect an external SPST latched (non-momentary) key switch to any
zone terminals given this designation and operate the keyswitch, as
follows:
After arming one or more partitions using the key switch and then
disarming using the keypad, the related partitions will be disarmed. In
order to arm the partition using the key switch again, turn the key to
the disarm position and then to the arm position.
If a key switch latch is assigned to more than one partition and one of
the partitions is armed by using the keypad (the key switch stays in the
disarm position), then:
o When changing the position of the key switch to the arm position,
all the disarmed partitions, which belong to this key switch, will be
armed.
o When turning the key switch to the disarm position, all the
partitions will be disarmed.