11
2017 Page 111 5IN2413 B
Quick keys Parameter Default Range
ZZZ
Entry Follower + Stay
All
Assigned to motion detectors and to interior doors protecting the area
between the entry door and the keypad, as follows:
• In partial (Stay) arming mode, a zone(s) given this designation behaves
like an Exit/Entry zone and is subject to the Entry and Exit Delay time
periods specified under Exit/Entry Delay 1. See Exit/Entry Delay 1,
above (
ZZZ) and .
• In full (Away) arming mode, a zone(s) given this designation behaves
like an Entry Follower Zone and causes an immediate intrusion alarm
when violated unless an Exit/Entry zone was violated first.
• If so, an Entry Follower + Stay zone(s) remains bypassed until the end
of the Entry Delay period.
ZZZ
Key Switch Delay
Used to apply the Exit/Entry Delay 1 parameter to the momentary key
switch operation. See Exit/Entry Delay 1, above (
ZZZ) and
.
ZZZ
Latch Key Switch Delay
Used to apply the Exit/Entry Delay 1 parameter to the latched key switch
operation. See Exit/Entry Delay 1, above (ZZZ) and
.
ZZZ
Tamper
For tamper detection. This zone operates the same as 24 hours zone, but it
has a special reporting code.
Note
For this zone type the zone sound is determined according to the Tamper
Sound defined under 1) System 4) Sound 1) Tamper
ZZZ
Technical
This zone operates the same as 24 hours zone, its report code should be
manually set according to the relevant detector connected to the zone.