Quick keys Parameter Default Range
ZZZ

Water
For flood or other types of water detectors. This zone operates the same as
24 hours zone, but it has a special flood report code.
ZZZ

Gas
For Gas (natural gas) leak detector. This zone operates the same as 24
hours zone, but it has a special gas report code.
ZZZ

CO
For CO (Carbon Monoxide) gas detectors. This zone operates the same as
24 hours zone, but it has a special CO report code.
ZZZ

Exit Term
This type of zone is used to avoid a false alarm by acting like an Exit
(OP)/Entry zone.
When triggered (after arming the system and closing the door or opening
the door, arming the system, and closing the door), the system's Exit Delay
time period will be shortened to 3 seconds.
When you re-open the door, the entry time restarts.
ZZZ

High Temperature
For detector temperature (hot or cold). This zone operates the same as 24
hours zone, but it has a special report code.
ZZZ

Low Temperature
For detector temperature (hot or cold). This zone operates the same as 24
hours zone, but it has a special report code.
ZZZ

Key Box
This zone is mainly used in Scandinavia. Triggering this zone will be
recorded in the event log. It can also be reported to the monitoring station.
No alarm is triggered.
When using this zone you should connect the alarm wiring of this zone
(usually the auxiliary contact of a door) to an external key box and the
tamper wiring to the housing switch.