2017 Page 166 5IN2413 B
Communication Monitoring Station Accounts
Quick Keys Parameter

Accounts
The number that recognizes the customer at the monitoring station,
you can define an account number for each monitoring station (1—3
possible). Account numbers are 6-digitnumbers in length, and are
assigned by the central station.
To edit an MS account number (code):
1. From the installer Programming menu, go to: 5 2 2
2. Scroll to the MS account (
, or ), and then press OK ().
3. Define/modify the code as needed, per the communication format
notes below:
Notes
Notes for Account Number in Contact ID Communication Format:
The account number will always be reported as 4 digits, for
example: A number defined as 000012 will be reported as 0012
If more than 4 digits were defined, the system always sends the
last 4 digits of the account number, for example: Account number
that was defined as 123456 will be sent as 3456.
In Contact ID you can place digits and letters A–F. The A
character is always sent as 0 for example: Account number that
was defined as 00C2AB will be sent as C20B.
N
otes for Account Number in SIA Communication Format:
Account number for SIA should be defined as a decimal number
(Only digits 0..9)
Account number can be reported as 1 to 6 digits. To send an
account number with less than 6 digits use the “0” digit, for
example: For account number 1234 enter 001234. In this case the
system will not send the “0” digit to the monitoring station.
In order to send the “0” digit in SIA format, located at the left
side of the number, use the “A” digit instead of the “0” digit. For
example, for account number 0407 enter 00A407, for a 6 digit
account number such as 001207 enter AA1207.