11
2017 Page 86 5IN2413 B
Quick keys Parameter Default Range
Global Follower
Yes Yes/No
YES: Specifies that all zones (that are programmed to follow an Exit/Entry
delay time) will follow the Exit/Entry delay time of any armed partition.
NO: Specifies that all zones (that are programmed to follow an entry delay
time) will follow the entry delay time of only the partitions to which they
are assigned.
Summer/Winter
No Yes/No
YES: The ProSYS Plus automatically sets its Time of Day clock one hour
ahead in the spring (on the last Sunday in March) and one hour back in the
Autumn (on the last Sunday in October).
NO: No automatic time accommodation is made.
24-Hour Bypass
No Yes/No
YES: It is possible for the user to bypass a 24-hour zone.
NO: It is not possible for the user to bypass a 24-hour zone.
Technician Tamper
No Yes/No
YES: It is necessary to enter the installer code to reset a tamper alarm ( ).
Therefore, resetting a tamper alarm requires the intervention of the alarm
company. However, the system can still be armed although the tamper
indication is on.
NO: Correcting the problem resets a tamper alarm, requiring no alarm
company assistance.
Technician Reset
No Yes/No
YES: It is necessary to enter the installer code to reset an alarmed partition
after it has been disarmed. This requires the intervention of the alarm
company technician/installer.
Note
Before the Ready LED ( ) can light, all zones within the partition must
be secured.
NO: Once an alarmed partition is reset the Ready LED lights when all
zones are secured.