Quick keys Parameter Default Range
 
Installer Tamper
Yes Yes/No
For above Grade 2, the system control bit “INSTALLER TAMPER”
shall be defined as YES.
YES: A Tamper event causes a lockout condition which can only be
reset by the installer code or by anti-code.
NO: A Tamper event does not cause a lockout condition
 
Low Battery Arming
Yes Yes/No
YES: Allows system arming when a low battery condition is detected (also
in the power supply expansion module).
NO: System arming is disabled when a low battery condition is detected.
 
Bell 30/10
No Yes/No
YES: Any internal sounders cease to sound for 10 seconds after each 30
seconds of operation.
NO: Any internal sounders operate without interruption.
 
Fire Temporal Pattern
No Yes/No
YES: During a fire alarm, the sirens produce a pattern of three short bursts
followed by a brief pause.
NO: During a fire alarm, the flow of sounds produced by the siren is a
pattern of two seconds ON, then two seconds OFF.
 
IMQ Install
No Yes/No
YES: Causes the following parameters to function as follows:
Auto Arm Bypass: If there is an open zone during the auto arm
process, the system will be armed, and a silent alarm will be
activated (unless the open zone is closed).
A utility output defined as “Auto Arm Alarm” is activated.
A utility output defined as “Zone Loss Alarm” is activated
Guard User: If a Guard user disarms a partition, the system will be
armed automatically after the predefined time period (see
Guard
Delay
page 80). If there is an open zone during the arming process,
the system will be armed, and an alarm will be sounded (unless the
open zone is closed).
NO: Causes the following parameters to function as follows:
Auto Arm Bypass: If the Auto Arm programming arms the system
and there is an open zone during the auto arm, the system will
bypass the open zones and arm the system.