Quick keys Parameter Default Range
 
Confirmation Speaker
No Yes/No
YES: A confirmed alarm triggers the internal sounder.
Note
A confirmed alarm actually eliminates the buzzer delay time, causing the
internal speaker to trigger immediately.
NO: The internal speaker will trigger normally (at the end of bell delay
time).
 
Bell Confirmation
No Yes/No
YES: A confirmed alarm triggers the external bell.
Note
A confirmed alarm actually eliminates the bell delay time, causing the
external alarm to start immediately.
NO: The external bell will trigger normally (at the end of bell delay time).
 
Error Speaker Time
Out
No Yes/No
This option determines the duration of the alarm that is generated via the
internal sounders (speakers) when the exit door is programmed as “Final
Exit”, and it is not closed once the exit time expires (an “EXIT ERROR”).
YES: The “EXIT ERROR” alarm in the internal speaker matches the alarm
bell timeout setting.
NO: The “EXIT ERROR” alarm in the internal speaker sounds
continuously until user reset.
 
Tamper Report
No Yes/No
This option determines if a tamper signal will be reported to the
monitoring station while the system is disarmed.
YES: A tamper signal will always be reported.
NO: A tamper signal will not be reported to the monitoring station during
the unset period.
Note
A tamper restore report to the monitoring station is always reported,
regardless of the “TAMPER REP” definition
 
AC Trouble Arm
Yes Yes/No
YES: The system can be armed with an AC trouble detected in the main
panel, power supply module or the bus sounder.
NO: The system cannot be armed with an AC trouble.