Quick keys Parameter Default Range
Strobe Arm
No Yes/No
This option allows the strobe (internal or external activated by a utility
output - Utility Output Follow Partition Strobe Trigger) to confirm
the final arming of the system.
YES: A ten-second strobe indication will occur after the system is armed.
NO: There will be no strobe indication when the system is armed.
Final Night
Yes Yes/No
This option determines the behavior of a final exit zone when the system is
armed at partial (Stay) arming.
YES: There is no need to open and close the door if the door is closed, in
order to arm the system in partial (Stay) arming. The zone behaves like a
regular “EXIT(OP)” zone type.
NO: There will be no change in the operation of a final exit zone in partial
(Stay) arming.
Stay Strobe
No Yes/No
YES: For partial (Stay) or group arming, a squawk indication will be made
by the strobe activated by an output (Utility Output Follow Partition
Strobe Trigger) at the end of the exit delay time.
NO: For partial (Stay) arming or group arming, no indication will be made
by the strobe at the end of the exit delay time.
Blank display
No Yes/No
YES: Two minutes after the last keypad operation, the display will appear
blank. After pressing any key, an "Enter Code" message will be displayed.
The user should enter his code or pass his proximity tag. The display
returns to the normal operation mode. Select this option for keypads that
can be viewed from outside the protected area to disguise the system
status.
NO: The keypad display operates normally