11
2017 Page 91 5IN2413 B
System Controls Communication
Quick keys Parameter Default Range
Communication
This section refers to controls of the systems communication capabilities.
Monitoring Station
Enable
Yes
Yes/No
YES: Enables communication with the monitoring station to report alarms,
trouble, and supervisory events.
NO: Disables communication with the monitoring station. Select NO for
installations that are not monitored by a monitoring station.
Follow Me Enable
Yes Yes/No
YES: Enables Follow-Me communication.
If both the monitoring station report and the FM report are defined, the
system will first call the monitoring station phones and then the FM
destinations.
Note
If FM is enabled and no voice module is installed then "beeps" will be sent
instead of messages.
NO: Disables Follow-Me communication.
Configuration Software
Enable
Yes Yes/No
YES: Enables communication between the alarm company (installer) and
the ProSYS Plus main panel using the Configuration Software. This enables
modifying an installation's configuration, obtaining status information, and
issuing main panel commands, all from a remote location.
NO: Disables communication, as detailed above.
Cloud Enable
Yes Yes/No
YES: Enables communication between the ProSYS Plus system and the
Cloud.
NO: Disables Cloud communication.