11
/
2017 Page 92 5IN2413 B
System Controls EN 50131
Quick keys Parameter Default Range

EN 50131
This section refers to controls that apply to EN 50131 approvals.

Authorize Installer
No Yes/No
This option limits the installer and sub-installer authorization to access the
programming menu.
YES: A Grand Master code is required to authorize the installer to enter the
programming mode for one hour.
NO: The installer does not need an authorization code.

Override Trouble
Yes Yes/No
Specifies if the system/partition can be armed when there is a trouble in the
system.
YES: The system will arm even if there is a trouble in the system.
NO: When the user starts the arming process and there is a system-trouble,
the user must confirm that he is aware of all troubles before continuing
with the arming process. The user needs to scroll the list of troubles. At the
end of the list the following question will appear: “Override Trouble?”
Toggle to Y (yes) and then press OK.

Restore Alarm
No Yes/No
YES: The user must confirm that s/he is aware that alarm occurred in the
system before rearming the system. The system/partition will be in “Not
Ready” status until it confirms the alarm. The user needs to confirm the
alarm by going to View Alarm Memory
NO: The user does not need to confirm the alarm before rearming the
system.

Mandatory Event Log
No Yes/No
YES: Only mandatory events (specified in the EN standard) will be
displayed in the event log.
NO: All the events will be displayed in the event log.