Quick keys Parameter Default Range

Restore Troubles
Yes Yes/No
For above Grade 2, the system control bit “Restore Troubles” shall be
defined as YES.
YES: A System Trouble condition must be acknowledged by the user.
NO: A System Trouble condition will reset automatically when clear.

Exit Alarm
Yes Yes/No
YES: A violated zone outside the exit route will generate an alarm during
the exit time. A report to the monitoring station for arming the system is
sent at the beginning of the arming procedure.
NO: A violated zone outside the exit route that remains open at the end of
the exit timer will cause a system fail-to-set condition. A report to the
monitoring station is sent at the end of a successful arming procedure.

Entry Alarm
No Yes/No
This feature is used to reduce false alarm reports to the monitoring station.
YES: The report to the monitoring station and the siren alarm will be
delayed for 30 seconds or until the end of the predefined entry delay (the
shorter time of the two) following a violation of a zone outside the entry
route.
NO: A violated zone outside the entry route will generate an alarm during
the entry time and a report will be sent to the monitoring station.

20 Minutes Signal
No Yes/No
YES: Prior to arming the system, the system will check for zones that did
not send a signal for more than 20 minutes. These zones will be regarded as
not ready. A partition assigned with a not ready zone cannot be armed.
NO: Prior to arming, the system will not check whether a zone did not send
a signal for more than 20 minutes.

Attenuation
No Yes/No
YES: The ProSYS Plus device will be attenuated by six dB during the
communication test.
NO: The ProSYS Plus device works in normal operation mode.