Loading...
Instrument Function
R&S
®
SMBV100A
264Operating Manual 1407.6062.32 ─ 08
SCPI command:
[:SOURce<hw>]:AWGN:POWer:NOISe on page 501
Noise Level (Total Bandwidth) - AWGN
Displays the level of the noise signal in the total bandwidth in "Noise Only" and "Additive
Noise" mode.
SCPI command:
[:SOURce<hw>]:AWGN:POWer:NOISe:TOTal on page 501
Carrier + Noise Level / Signal + Noise Level (System Bandwidth) / Carrier + Inter-
ferer Level / Signal + Interferer Level
(Additive Noise and CW Interferer)
Displays the overall level of the noise/interferer signal plus useful signal.
The name of this parameter depends on the selected "Display Mode".
SCPI command:
[:SOURce<hw>]:AWGN:POWer:SUM on page 502
Carrier + Noise PEP / Signal + Noise PEP (Total Bandwidth) / Carrier + Interferer
PEP / Signal + Interferer PEP
(Additive Noise and CW Interferer)
Displays the peak envelope power of the overall signal comprised of noise signal plus
useful signal.
The name of this parameter depends on the selected "Display Mode".
Note: The peak envelope power (PEP) specified in the header corresponds to the PEP
value of the carrier.
SCPI command:
[:SOURce<hw>]:AWGN:POWer:SUM:PEP on page 503
5.6.3 Output of the Baseband Signal - I/Q Out
The R&S Signal Generator provides various outputs of the baseband signal.
Impairment of Digital I/Q Signal and Noise Generator - AWGN/IMP Block