Remote Control Commands
R&S
®
SMBV100A
476Operating Manual 1407.6062.32 ─ 08
Function/Digital
Standard
List type Contents File suffix
"DAB/T-DMB" Settings Complete setting of the DAB/T-DMB menu
*.dab
Settings DAB ETI Files
*.eti
*.xeti
7.11.3 Examples
In these examples, the current instrument setting is stored in the file
test1.savrcltxt in the directory user.
Storing and Loading Current Settings
1. Store the current setting in an intermediate memory with number 4. This setting can
be called using command *RCL and the associated number of the memory, e.g. *RCL
4.
*SAV 4
2. To store the settings in a file in a specific directory, specify the complete path.
MMEM:STOR:STAT 4,"var/user/test.savrcltxt"
3. To store the settings in a file in the default drive, set the default drive and specify only
the file name.
MMEM:CDIR 'var/user'*SAV 4
MMEM:STOR:STAT 4,"test.savrcltxt"
4. Load the file test.savrcltxt in the user directory.
MMEM:LOAD:STAT 4,'/var/smbv/user/test.savrcltxt'
5. Activate the instrument setting of the file test.savrcltxt.
*RCL 4
Working with Files and Directories
1. Read out all files in the specified directory.
MMEM:CAT? '/usb/user'
Response: 127145265,175325184,"test,DIR,0","temp,DIR,
0","readme.txt,ASC,1324","state.savrcltxt,STAT,
5327","waveform.wv,BIN,2342"
the directory /usb/user contains the subdirectories test and temp as well as the
files readme.txt, state.savrcltxt and waveform.wv which have different file
types.
Tip: To query only the subdirectories of the current or specified directory, perform:
MMEM:DCAT? '/usb/user'
Response: 'test', 'temp'
To query only the number of subdirectories in the current or specified directory, per-
form:
MMEMory Subsystem