Remote Control Commands
R&S
®
SMBV100A
547Operating Manual 1407.6062.32 ─ 08
Example:
MMEM:CDIR '/var/smbv/user/waveform'
sets the default directory to root/user/waveform.
BB:ARB:WSEG:NEXT 2
selects segment 2 to be output.
BB:ARB:TRIG:SMOD NEXT
selects extended trigger mode next, i.e. the segment specified with
command :BB:ARB:WSEG:NEXT will be output.
BB:ARB:SEQ AUTO
selects trigger mode Auto.
BB:ARB:WAV:SEL 'multi_wv1'
loads multi segment waveform multi_wv1.wv. Generation of
segment 2 starts.
BB:ARB:WSEG:NEXT 3
switched at once to output of segment 3.
[:SOURce<hw>]:BB:ARB:WSEGment:NEXT:EXECute
Triggers manually switchover to the subsequent segment in the mutli segment file. A
manual trigger can be executed only when an internal next segment source
(BB:ARB:WSEG:NEXT:SOUR INT) has been selected.
To perform a switchover to any segment within the multi segment file, select the next
segment with the command BB:ARB:WSEG:NEXT.
This command is disabled, if a sequencing play list is enabled.
Example:
BB:ARB:WSEG:NEXT:SOUR INT
selects internal next segment source.
BB:ARB:WSEG:NEXT 2
selects segment 2 to be output.
BB:ARB:WSEG:NEXT:EXEC
executes a switchover to the next segment.
Usage: Event
[:SOURce<hw>]:BB:ARB:WSEGment:NEXT:SOURce <Source>
Selects the next segment source, i.e. determines whether the next segment is switched
upon receiving of an external trigger signal or upon executing of software trigger .
Parameters:
<Source> INTernal | NEXT
INTernal
Switch over to any segment is triggered manually by means of the
command BB:ARB:WSEG:NEXT:EXEC.
NEXT
The trigger event for switching to the next segment is input on the
NEXT connector.
*RST: INTernal
SOURce Subsystem