Parameters:
<Mode> UNCHanged | HIGHest | USER
UNCHanged
The segments are output with the clock rate defined in the wave-
form file. Extended Trigger Mode "Next Segment Seamless"
(:BB:ARB:TRIG:SMOD NSEam) can only be selected if all seg-
ments have the same clock rate. Extended Trigger Mode "Next
Segment" (:BB:ARB:TRIG:SMOD NEXT) can only be selected if
trigger mode "Internal" is selected (:BB:ARB:TRIG:SOUR INT).
HIGHest
The segments are output at the highest available clock rate.
USER
The segments are output with the clock rate defined with com-
mand :BB:ARB:WSEG:CONF:CLOC
*RST:
UNCHanged
Example:
BB:ARB:WSEG:CONF:CLOC:MODE UNCH
selects clock mode unchanged. The segments are output with the
clock rate defined in the waveform file.
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:COMMent <Comment>
This command enters a comment for the configuration file. The configuration file must be
specified with command :BB:ARB:WSEG:CONF:SEL.
Parameters:
<Comment> string
Example:
BB:ARB:WSEG:CONF:COMM <3gpp_up>
enters comment "3gpp_up".
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:DELete <Filename>
This command deletes the configuration file. The configuration files are used to create
multi segment waveform files.
Setting parameters:
<Filename> string
Example:
MMEM:CDIR '/var/smbv/user/waveform'
sets the default directory to /var/smbv/user/waveform.
BB:ARB:WSEG:CONF:DEL 'multi1'
deletes configuration file multi1.inf_mswv.
Usage: Setting only
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:LEVel[:MODE] <Mode>
This command selects the level mode for the multi segment waveform.
SOURce Subsystem