Remote Control Commands
R&S
®
SMBV100A
674Operating Manual 1407.6062.32 ─ 08
Example:
PM:STAT ON
activates PM modulation.
Usage: SCPI confirmed
7.14.17 SOURce:POWer Subsystem
This subsystem contains the commands for setting the output level, level control and level
correction of the RF signal.
Other units can also be used instead of dBm:
●
by entering the unit directly after the numerical value (example :POW 0.5V)
● by changing the DEFault unit in the UNIT system (see the command :UNIT:
POWer).
[:SOURce<hw>]:POWer:ALC:OMODe.............................................................................674
[:SOURce<hw>]:POWer:ALC:SONCe..............................................................................675
[:SOURce<hw>]:POWer:ALC[:STATe].............................................................................675
[:SOURce<hw>]:POWer:ATTenuation:RFOFf:MODE.........................................................676
[:SOURce<hw>]:POWer[:LEVel][:IMMediate][:AMPLitude]..................................................676
[:SOURce<hw>]:POWer[:LEVel][:IMMediate]:OFFSet........................................................677
[:SOURce<hw>]:POWer[:LEVel][:IMMediate]:RCL.............................................................677
[:SOURce<hw>]:POWer:LIMit[:AMPLitude].......................................................................678
[:SOURce<hw>]:POWer:LMODe.....................................................................................678
[:SOURce<hw>]:POWer:MANual.....................................................................................679
[:SOURce<hw>]:POWer:MODE.......................................................................................680
[:SOURce<hw>]:POWer:PEP..........................................................................................680
[:SOURce<hw>]:POWer:POWer......................................................................................680
[:SOURce<hw>]:POWer:SPC:CRANge............................................................................681
[:SOURce<hw>]:POWer:SPC:DELay...............................................................................681
[:SOURce<hw>]:POWer:SPC:PEAK................................................................................682
[:SOURce<hw>]:POWer:SPC:SELect..............................................................................682
[:SOURce<hw>]:POWer:SPC:STATe...............................................................................682
[:SOURce<hw>]:POWer:SPC:TARGet.............................................................................682
[:SOURce<hw>]:POWer:STARt.......................................................................................683
[:SOURce<hw>]:POWer:STEP[:INCRement]....................................................................683
[:SOURce<hw>]:POWer:STEP:MODE.............................................................................683
[:SOURce<hw>]:POWer:STOP........................................................................................684
[:SOURce<hw>]:POWer:ALC:OMODe <OffMode>
The command sets the level control mode which becomes active when automatic level
control is deactivated (ALC Off).
SOURce Subsystem