Remote Control Commands
R&S
®
SMBV100A
541Operating Manual 1407.6062.32 ─ 08
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:CATalog?
This command queries the available configuration files in the specified default directory.
The configuration files are used to create multi segment waveform files.
Return values:
<Catalog> string
Example:
MMEM:CDIR '/var/smbv/user/waveform'
sets the default directory to /var/smbv/use/waveform.
BB:ARB:WSEG:CONF:CAT?
reads out all the configuration files in the default directory.
Response: mulit1, multi2
the directory contains the configuration files multi1.inf_mswv
and multi2.inf_mswv.
Usage: Query only
[:
SOURce<hw>]:BB:ARB:WSEGment:CONFigure:CLOCk <Clock>
This command defines the clock rate used for multi segment waveform output in case of
Clock Mode "User" (:BB:ARB:WSEG:CONF:CLOCk:MODE USER).
Parameters:
<Clock> float
Increment: 1E-3
*RST: max SampleRate
Example:
BB:ARB:WSEG:CONF:CLOC:MODE USER
selects Clock Mode User.
BB:ARB:WSEG:CONF:CLOC 50MHz
defines a clock rate of 50 MHz.
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:CLOCk:MODE <Mode>
This command selects the clock rate mode for the multi segment waveform.
SOURce Subsystem