Remote Control Commands
R&S
®
SMBV100A
521Operating Manual 1407.6062.32 ─ 08
Example:
BB:ARB:TSIG:SINE:PHAS 90
sets a phase offset of 90 degrees.
[:SOURce<hw>]:BB:ARB:TSIGnal:SINE:SAMPles <Samples>
The command sets the sample rate for the sine signal in samples per period.
The resulting clock rate must not exceed the maximum ARB clock rate of 150 or 90 MHz
depending on the installed options.
The maximum value is automatically restricted by reference to the set frequency and has
to fulfill the rule Frequency * Samples <= ARB clock rate.
Parameters:
<Samples> integer
Range: 4 to 1000
Increment: 1
*RST: 100
Default unit: 100 samples per period
Example:
BB:ARB:TSIG:SINE:SAMP 100
sets a sample rate of 100 samples per period.
SOURce:BB:ARB:MCAR Subsystem
The MCARrrier subsystem contains the commands for setting the Multi Carrier Wave-
form Generator.
Section chapter 7.3, "R&S Signal Generator Waveform and List Format", on page 439
describes the ARB waveform format and how it is used to transmit waveforms via the IEC
bus.
CARRier<ch>
The numerical suffix under CARRier distinguish between the carriers. The value range
is 0 .. 31.
[:SOURce<hw>]:BB:ARB:MCARrier:CARRier:COUNt........................................................522
[:SOURce<hw>]:BB:ARB:MCARrier:CARRier:MODE.........................................................522
[:SOURce<hw>]:BB:ARB:MCARrier:CARRier:SPACing.....................................................523
[:SOURce<hw>]:BB:ARB:MCARrier:CARRier<ch>:CONFlict..............................................523
[:SOURce<hw>]:BB:ARB:MCARrier:CARRier<ch>:DELay.................................................524
[:SOURce<hw>]:BB:ARB:MCARrier:CARRier<ch>:FILE....................................................524
[:SOURce<hw>]:BB:ARB:MCARrier:CARRier<ch>:FREQuency..........................................524
[:SOURce<hw>]:BB:ARB:MCARrier:CARRier<ch>:PHASe.................................................525
[:SOURce<hw>]:BB:ARB:MCARrier:CARRier<ch>:POWer.................................................525
[:SOURce<hw>]:BB:ARB:MCARrier:CARRier<ch>:STATe.................................................525
[:SOURce<hw>]:BB:ARB:MCARrier:CFACtor:MODE.........................................................525
[:SOURce<hw>]:BB:ARB:MCARrier:CLIPping:CFACtor.....................................................526
[:SOURce<hw>]:BB:ARB:MCARrier:CLIPping:CUToff........................................................526
[:SOURce<hw>]:BB:ARB:MCARrier:CLIPping[:STATe]......................................................527
[:SOURce<hw>]:BB:ARB:MCARrier:CLOad......................................................................527
SOURce Subsystem