Instrument Function
R&S
®
SMBV100A
268Operating Manual 1407.6062.32 ─ 08
5.7.1 Digital I/Q Output General Settings
State - Digital I/Q Output
Switches On/Off the digital I/Q output signal.
SCPI command:
[:SOURce<hw>]:IQ:OUTPut:DIGital:STATe on page 647
5.7.2 Sample Rate
In the "Sample Rate" section the sample rate for the digital I/Q output signal can be set
and the state of signal transmission is indicated by the FIFO Status.
Sample Rate Source - Digital I/Q Output
Selects the source for the sample rate of the digital I/Q output signal.
"User Defined"
The internally generated clock reference signal is used. The sample
rate is calculated and displayed in the field "Value".
"Digital I/Q Out"
An external clock reference signal is used. The clock signal is directly
fed in via pin CLK2 of the digital output interface (option R&S SMBV-
K18, Digital Baseband Connectivity). The sample rate is estimated and
displayed in the field "Value".
Note: Estimation works best if the sample rate is close to the user
defined value.
SCPI command:
[:SOURce<hw>]:IQ:OUTPut:DIGital:SRATe:SOURce on page 647
Digital I/Q Output Settings