Rohde & Schwarz SMBV100A - Description of Individual Diagram Blocks of the RF Section

Rohde & Schwarz SMBV100A
780 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Getting Started
R&S
®
SMBV100A
55Operating Manual 1407.6062.32 ─ 08
R&S SMBV-B106 (up to 6 GHz)
For detailed information on available options, refer to the R&S SMBV data sheet and the
R&S SMBV Configuration guide.
Up-to-date information is available at R&S SMBV homepage on the internet http://
www2.rohde-schwarz.com/product/smbv100a.html).
3.3.1 Description of Individual Diagram Blocks of the RF Section
This section gives an overview of the available blocks and a detailed descritption of their
functions.
I/Q Mod A block
The (first) I/Q modulator is configured in this block. Also the Analog Wideband I/Q mode
can be selected here, which allows external I/Q signals to be directly applied to the I/Q
modulator, i.e. not via the baseband section. If no baseband modules are installed, I/Q
modulation is possible only in the Analog Wideband I/Q mode.
I and Q components can also be swapped (I/Q Swap). (Analog) I/Q impairments can be
set in addition. Unlike the impairments in the "AWGN/IMP" block, impairments in the "I/
Q Mod" block also affect the externally applied signals in the Analog Wideband I/Q mode.
The status display in the block shows whether I/Q impairments and/or I/Q swap is active.
I/Q modulation is switched on or off with the TOGGLE ON/OFF key.
Note: An I/Q modulator provided in the R&S SMBV is automatically activated when a
connected baseband source is switched on. The I/Q modulator can also be separately
switched on and off (select the "I/Q Mod" block and press the TOGGLE ON/OFF key).
This permits the following configuration to be obtained with a single-path R&S SMBV.
The baseband source generates an I/Q signal that is output via the analog I/Q output. At
the same time, the RF section generates an unmodulated carrier.
RF/A Mod A block
In this block, the RF parameters and the analog modulation modes are set.
The active analog modulation modes are displayed in the block. The TOGGLE ON/
OFF key switches the RF signal on and off. When the RF signal is switched off, the switch
before the RF output symbol is open.
RF settings include:
Frequency and reference frequency
Attenuator settings.
Frequency and level sweep
List Mode settings. In this mode, extremely fast frequency and level settings can be
made.
Note: Numeric values for frequency and level are entered best and quickest with the aid
of the FREQ and LEVEL keys.
Available analog modulation modes:
Amplitude modulation
Pulse modulation (option R&S SMBV-K22).
Note: For modulation modes that can be simultaneously used, refer to the R&S SMBV
data sheet.