[:SOURce<hw>]:BB:MCCW:CLOCk:SYNChronization:EXECute
Performs automatically adjustment of the instrument's settings required for the synchro-
nization mode, set with the command [:SOURce<hw>]:BB:MCCW:CLOCk:
SYNChronization:MODE.
Example:
BB:MCCW:CLOC:SYNC:MODE MAST
the instrument is configured to work as a master one.
BB:MCCW:CLOC:SYNC:EXEC
all synchronization's settings are adjusted accordingly.
Usage: Event
7.14.4 SOURce:BBIN Subsystem
The SOURce:BBIN subsystem contains the commands for setting the external digital and
analog baseband signals.
The external baseband signal A can be routed to path A, path B, or both paths. The
external baseband signal B can be routed to path B only.
[:SOURce]:BBIN:ALEVel:EXECute..................................................................................610
[:SOURce<hw>]:BBIN:CDEVice......................................................................................610
[:SOURce]:BBIN:CFACtor...............................................................................................611
[:SOURce<hw>]:BBIN:DIGital:ASETting:STATe................................................................611
[:SOURce]:BBIN:FOFFset...............................................................................................611
[:SOURce]:BBIN:IQSWap[:STATe]..................................................................................612
[:SOURce<hw>]:BBIN:MPERiod......................................................................................612
[:SOURce]:BBIN:OLOad:HOLD:RESet.............................................................................612
[:SOURce]:BBIN:OLOad:HOLD:STATe............................................................................613
[:SOURce]:BBIN:OLOad:STATe......................................................................................613
[:SOURce]:BBIN:POWer:PEAK.......................................................................................613
[:SOURce]:BBIN:POWer:RMS.........................................................................................614
[:SOURce]:BBIN:SRATe:ACTual.....................................................................................614
[:SOURce<hw>]:BBIN:SRATe:FIFO[:STATus]..................................................................614
[:SOURce<hw>]:BBIN:SRATe:SOURce...........................................................................615
[:SOURce]:BBIN:STATe.................................................................................................615
[:SOURce]:BBIN:ALEVel:EXECute
This command starts measuring the input signal. The measurement estimates the crest
factor and the peak power.
Example:
BBIN:ALEV:EXEC
starts measuring the input signal.
Usage: Event
[:SOURce<hw>]:BBIN:CDEVice?
Digital Input only.