Remote Control Commands
R&S
®
SMBV100A
544Operating Manual 1407.6062.32 ─ 08
Parameters:
<Mode> OFF | MRK1 | MRK2 | MRK3 | MRK4
OFF
No additional marker is generated.
MRK1|MRK2|MRK3|MRK4
Generates a restart marker signal at the beginning of the first seg-
ment for the corresponding marker.
Use this setting to generate a restart marker for the complete
sequence.
*RST: OFF
Example:
BB:ARB:WSEG:CONF:SEL 'ConfComm'
BB:ARB:WSEG:CONF:MARK:FSEG MRK3
[:
SOURce<hw>]:BB:ARB:WSEGment:CONFigure:MARKer:MODE <Mode>
Defines the way the marker information within the separate segments is processed.
Parameters:
<Mode> IGNore | TAKE
IGNore
The marker information carried in the individual segment wave-
form files is not considered.
TAKE
The output waveform file contains the marker information as con-
figured in the individual waveform files.
*RST: TAKE
Example:
BB:ARB:WSEG:CONF:SEL 'ConfComm'
BB:ARB:WSEG:CONF:MARK:MODE TAKE
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:OFILe <OFile>
This command defines the file name for the multi segment waveform. This file name is
stored in the configuration file and is used when a waveform is created (com-
mand :BB:ARB:WSEG:CLOad or :BB:ARB:WSEG:CREate). The file extension is
*.wv.
Parameters:
<OFile> string
Example:
MMEM:CDIR '/var/smbv/user/waveform'
sets the default directory to /var/smbv/user/waveform.
BB:ARB:WSEG:CONF:SEL 'multi1'
creates the configuration file multi1.inf_mswv in default direc-
tory.
BB:ARB:WSEG:CONF:OFIL 'mseg1_2'
defines the file name mseg1_2.wv for the multi segment wave-
form file created using configuration file multi1.inf_mswv.