Remote Control Commands
R&S
®
SMBV100A
543Operating Manual 1407.6062.32 ─ 08
Parameters:
<Mode> UNCHanged | ERMS
UNCHanged
The segments are output exactly as defined in the files.
ERMS
The segments are output so that all segments have the same rms
value.
*RST:  UNCHanged
Example: 
BB:ARB:WSEG:CONF:LEV:MODE UNCH
selects level mode unchanged. The segments are output as
defined in the waveform file.
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:MARKer:ESEGment <Mode>
Enables/disables the generation of an additional marker restart signal in the output wave-
form file.
If additional marker generation is enabled, the existing marker signals in the individual
segment waveform files are not considered.
Parameters:
<Mode> OFF | MRK1 | MRK2 | MRK3 | MRK4
OFF
No additional marker is generated.
MRK1|MRK2|MRK3|MRK4
Generates a restart marker signal at the beginning of each seg-
ment for the corresponding marker.
The segment begin is defined by the low-high slope of the marker.
This applies for switching between two segments as well as in
case of segment replay.
*RST:  OFF
Example: 
BB:ARB:WSEG:CONF:SEL 'ConfComm'
BB:ARB:WSEG:CONF:MARK:ESEG MRK3
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:MARKer:FSEGment <Mode>
Enables/disables the generation of an additional marker restart signal in the output wave-
form file.
If additional marker generation is enabled, the existing marker signals in the individual
segment waveform files are not considered.
SOURce Subsystem