EasyManua.ls Logo

Rohde & Schwarz SMBV100A - Rcl; Rst; Sav; Sre

Rohde & Schwarz SMBV100A
780 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMBV100A
436Operating Manual 1407.6062.32 ─ 08
Parameters:
<Action> 0 | 1
0
The contents of the status registers are preserved.
1
Resets the status registers.
*RCL <Number>
ReCaLl calls up the instrument settings from an intermediate memory identified by the
specified number. The instrument settings can be stored to this memory using the com-
mand *SAV with the associated number.
It also activates the instrument settings which are stored in a file and loaded using the
MMEMory:LOAD <number>, <file_name.extension> command.
*RST
ReSeT
Sets the instrument to a defined default status. The default settings are indicated in the
description of commands.
The command is equivalent to SYSTem:PRESet.
Usage:
Setting only
*SAV <Number>
SAVe stores the current instrument settings under the specified number in an intermedi-
ate memory. The settings can be recalled using the command *RCL with the associated
number.
To transfer the stored instrument settings in a file, use the command :MMEMory:
STORe:STATe.
*SRE <Contents>
Service Request Enable
Sets the service request enable register to the indicated value. This command determines
under which conditions a service request is triggered.
Parameters:
<Contents> Contents of the service request enable register in decimal form.
Bit 6 (MSS mask bit) is always 0.
Range: 0 to 255
Common Commands