Remote Control Commands
R&S
®
SMBV100A
540Operating Manual 1407.6062.32 ─ 08
Example:
MMEM:CDIR '/var/smbv/user/waveform'
sets the default directory to /var/smbv/user/waveform.
BB:ARB:WSEG:CONF:SEL 'multi_sin'
creates the configuration file multi_sin.inf_mswv in the
default directory.
BB:ARB:WSEG:CONF:SEGM:APP 'sinus1'
includes waveform sinus1.wv as segment 1 in the configuration
file. The waveform must be available in the default directory.
BB:ARB:WSEG:CONF:SEGM:APP 'sinus2'
includes waveform sinus2.wv as segment 2 in the configuration
file. The waveform must be available in the default directory.
BB:ARB:WSEG:CONF:OFIL 'mseg1_2'
defines the file name mseg1_2.wv for the multi segment wave-
form.
BB:ARB:WSEG:CLO 'multi_sin'
creates multi segment waveform mseg1_2.wv using the settings
of the configuration file multi_sin.inf_mswv.
The new multi segment waveform is loaded and digital standard
"ARB" is activated.
Usage:
Setting only
[:SOURce<hw>]:BB:ARB:WSEGment:CONFigure:BLANk:APPend <SampCount>,
<Frequency>
Adds a blank segment to the multi segment file.
Setting parameters:
<SampCount> float
Specifies the number of samples.
Range: 512 to 1E7
Increment: 1
*RST: 1000
<Frequency> float
Determines the clock rate.
Range: 400 Hz to Max (depends on instrument type)
Increment: 0.001
*RST: 1E8
Example:
SOUR:BB:ARB:WSEG:CONF:SEL "MSegFile"
selects a multi segment file.
SOUR:BB:ARB:WSEG:CONF:BLAN:APP 1000,100000000
adds a blank segment with 1000 samples and 100 MHz clock rate
to the selected multi segment file
Usage: Setting only
SOURce Subsystem