Remote Control Commands
R&S
®
SMBV100A
549Operating Manual 1407.6062.32 ─ 08
7.14.3.3 SOURce:BB:DM Subsystem
The commands in the SOURce:BB:DM subsystem are described in two sections, sepa-
rated into configuring digital modulation and lists for digital modulation.
DM General Remote-Control Commands
The following section contains the commands for generating the digital modulation signal.
● Common Settings..................................................................................................549
● Clock Settings.......................................................................................................552
● Trigger Settings.....................................................................................................554
● Marker Settings.....................................................................................................560
● Filter Settings........................................................................................................563
● Modulation Settings...............................................................................................566
● Power Ramp.........................................................................................................569
Common Settings
[:SOURce<hw>]:BB:DM:PATTern....................................................................................549
[:SOURce<hw>]:BB:DM:PRBS[:LENGth]..........................................................................549
[:SOURce<hw>]:BB:DM:PRESet.....................................................................................550
[:SOURce<hw>]:BB:DM:SOURce....................................................................................550
[:SOURce<hw>]:BB:DM:SRATe......................................................................................551
[:SOURce<hw>]:BB:DM:STANdard..................................................................................551
[:SOURce<hw>]:BB:DM:STATe.......................................................................................551
[:SOURce<hw>]:BB:DM:SWITching:SOURce...................................................................552
[:SOURce<hw>]:BB:DM:SWITching:STATe......................................................................552
[:SOURce<hw>]:BB:DM:PATTern <Pattern>
The command selects the data pattern for the internal data when PATTern is selected
as the data source. The maximum length is 64 bits.
Parameters:
<Pattern> integer
Range: #B0,1 to #B111...1,64
*RST: #B0,1
Example:
BB:DM:SOUR PATT
selects Pattern as the data source for digital modulation.
BB:DM:PATT #B01110111010101010,17
generates the user-defined sequence of 0/1 data.
[:SOURce<hw>]:BB:DM:PRBS[:LENGth] <Length>
The command defines the length of the pseudo-random sequence in accordance with
the following equation:
Length = (2^Length) - 1