EasyManua.ls Logo

Rohde & Schwarz SMBV100A - Source:bb:DM Subsystem

Rohde & Schwarz SMBV100A
780 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Control Commands
R&S
®
SMBV100A
549Operating Manual 1407.6062.32 ─ 08
7.14.3.3 SOURce:BB:DM Subsystem
The commands in the SOURce:BB:DM subsystem are described in two sections, sepa-
rated into configuring digital modulation and lists for digital modulation.
DM General Remote-Control Commands
The following section contains the commands for generating the digital modulation signal.
Common Settings..................................................................................................549
Clock Settings.......................................................................................................552
Trigger Settings.....................................................................................................554
Marker Settings.....................................................................................................560
Filter Settings........................................................................................................563
Modulation Settings...............................................................................................566
Power Ramp.........................................................................................................569
Common Settings
[:SOURce<hw>]:BB:DM:PATTern....................................................................................549
[:SOURce<hw>]:BB:DM:PRBS[:LENGth]..........................................................................549
[:SOURce<hw>]:BB:DM:PRESet.....................................................................................550
[:SOURce<hw>]:BB:DM:SOURce....................................................................................550
[:SOURce<hw>]:BB:DM:SRATe......................................................................................551
[:SOURce<hw>]:BB:DM:STANdard..................................................................................551
[:SOURce<hw>]:BB:DM:STATe.......................................................................................551
[:SOURce<hw>]:BB:DM:SWITching:SOURce...................................................................552
[:SOURce<hw>]:BB:DM:SWITching:STATe......................................................................552
[:SOURce<hw>]:BB:DM:PATTern <Pattern>
The command selects the data pattern for the internal data when PATTern is selected
as the data source. The maximum length is 64 bits.
Parameters:
<Pattern> integer
Range: #B0,1 to #B111...1,64
*RST: #B0,1
Example:
BB:DM:SOUR PATT
selects Pattern as the data source for digital modulation.
BB:DM:PATT #B01110111010101010,17
generates the user-defined sequence of 0/1 data.
[:SOURce<hw>]:BB:DM:PRBS[:LENGth] <Length>
The command defines the length of the pseudo-random sequence in accordance with
the following equation:
Length = (2^Length) - 1