Loading...
Remote Control Commands
R&S
®
SMBV100A
552Operating Manual 1407.6062.32 ─ 08
Enabling digital modulation (BB:DM:STAT ON) turns off all the other standards.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: OFF
Example:
BB:DM:STAT ON
switches digital modulation on.
[:SOURce<hw>]:BB:DM:SWITching:SOURce <Source>
The command selects the source of the CW control signal for switching between a modu-
lated and an unmodulated signal.
Parameters:
<Source> INTernal
INTernal
The CW signal in the control list is used for the control.
*RST: INTernal
Example:
BB:DM:SWIT INT
the CW signal in the control list is used for the control.
[:SOURce<hw>]:BB:DM:SWITching:STATe <State>
The command enables switching between a modulated and an unmodulated signal.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
BB:DM:SWIT:STAT INT
CW switching is active.
Clock Settings
[:SOURce<hw>]:BB:DM:CLOCk:MODE............................................................................552
[:SOURce<hw>]:BB:DM:CLOCk:MULTiplier......................................................................553
[:SOURce<hw>]:BB:DM:CLOCk:SOURce........................................................................553
[:SOURce<hw>]:BB:DM:CLOCk:SYNChronization:MODE..................................................553
[:SOURce<hw>]:BB:DM:CLOCk:SYNChronization:EXEcute...............................................554
[:SOURce<hw>]:BB:DM:CLOCk:MODE <Mode>
The command enters the type of externally supplied clock (:BB:DM:CLOCk:SOURce
EXTernal).
Parameters:
<Mode> SYMBol | MSYMbol
*RST: SYMBol