ARB:STAT ON is only possible after the selection of a waveform. The selected waveform
is output straight away (ARB:SEQ AUTO|RETRigger) or after the first trigger event
(ARB:SEQ AAUT|ARET), depending on the trigger setting.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
BB:ARB:WAV:SEL 'wave1'
loads waveform file wave1.wv from the default directory.
BB:ARB:TRIG:SEQ RETR
sets trigger mode Retrigger.
BB:ARB:STAT ON
switches on the ARB generator. The selected waveform is output
straight away. A trigger event causes signal output to restart.
Clock Settings
[:SOURce<hw>]:BB:ARB:CLOCk.....................................................................................506
[:SOURce<hw>]:BB:ARB:CLOCk:MODE..........................................................................506
[:SOURce<hw>]:BB:ARB:CLOCk:MULTiplier....................................................................507
[:SOURce<hw>]:BB:ARB:CLOCk:SOURce.......................................................................507
[:SOURce<hw>]:BB:ARB:CLOCk:SYNChronization:MODE................................................507
[:SOURce<hw>]:BB:ARB:CLOCk:SYNChronization:EXECute.............................................508
[:SOURce<hw>]:BB:ARB:CLOCk <Clock>
The command sets the clock rate in samples. Loading a waveform waveform
(ARB:WAV:SEL <name>) sets the clock rate that is defined in the waveform tag 'clock'.
The command subsequently changes the clock rate; see data sheet for value range.
In the case of an external clock source (selection ARB:CLOCk:SOURce EXTernal) the
clock for the external source must be entered with this command.
Parameters:
<Clock> float
Range: 400 Hz to 100 MHz
Increment: 0.001 Hz
*RST: 1 MHz
Example:
BB:ARB:CLOC:SOUR INT
selects the internal clock source for generating waveforms.
BB:ARB:CLOC 0.5 MHz
sets the clock rate to 0.5 MHz.
[:SOURce<hw>]:BB:ARB:CLOCk:MODE <Mode>
The command enters the type of externally supplied clock (:BB:ARB:CLOCk:SOURce
EXTernal). When MSAMple is used, a multiple of the sample clock is supplied via the
CLOCK connector and the sample clock is derived internally from this. The multiplier is
entered with the command :BB:ARB:CLOCk:MULTiplier.