Remote Control Commands
R&S
®
SMBV100A
507Operating Manual 1407.6062.32 ─ 08
Parameters:
<Mode> SAMPle | MSAMple
*RST: SAMPle
Example:
BB:ARB:CLOC:MODE SAMP
selects clock type "Sample", i.e. the supplied clock is a sample
clock.
[:SOURce<hw>]:BB:ARB:CLOCk:MULTiplier <Multiplier>
The command specifies the multiplier for clock type "Multiple Samples"
(:BB:ARB:CLOCk:MODE MSAM) in the case of an external clock source.
Parameters:
<Multiplier> integer
Range: 1 to 64
*RST: 4
Example:
BB:ARB:CLOC:SOUR EXT
selects the external clock source. The clock is supplied via the
CLOCK connector.
BB:ARB:CLOC:MODE MSAM
selects clock type Multiple Samples, i.e. the supplied clock has a
rate which is a multiple of the sample rate.
BB:ARB:CLOC:MULT 12
The multiplier for the external clock rate is 12.
[:SOURce<hw>]:BB:ARB:CLOCk:SOURce <Source>
The command selects the source for the digital modulation clock.
Parameters:
<Source> INTernal | EXTernal | AINTernal
INTernal
The internal clock reference is used.
EXTernal
The external clock reference is supplied to the CLOCK connector.
*RST: INTernal
Example:
BB:ARB:CLOC:SOUR EXT
selects an external clock reference. The clock is supplied via the
CLOCK connector.
BB:ARB:CLOC:MODE SAMP
enters clock type sample.
[:SOURce<hw>]:BB:ARB:CLOCk:SYNChronization:MODE <Mode>
Selects the synchronization mode.
SOURce Subsystem