Remote Control Commands
R&S
®
SMBV100A
612Operating Manual 1407.6062.32 ─ 08
Parameters:
<FOffset> float
Range: -40E6 to 40E6
Increment: 0.01
*RST: 0
Default unit: Hz
Example:
BBIN:FOFF 2 MHz
sets a frequency offset of 2 MHz.
[:SOURce]:BBIN:IQSWap[:STATe] <State>
This command swaps the I and Q channel if set to ON.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Example:
BBIN:IQSW ON
swaps the I and Q channel of the external baseband signal.
[:SOURce<hw>]:BBIN:MPERiod <MPeriod>
Sets the recording duration for measuring the baseband input signal by Auto Level Set.
Parameters:
<MPeriod> float
Range: 1 to 32
Increment: 1
*RST: 2
Default unit: s
Example:
BBIN:MPER 4s
sets the recording duration for Auto Level Set to 4 seconds.
[:SOURce]:BBIN:OLOad:HOLD:RESet
This command executes a reset of the Overload Hold State and LED.
Example:
BBIN:MODE DIG
selects the digital baseband input mode.
BBIN:OLO:HOLD:RES
resets the overload hold state.